Netrality – 210 N Tucker St St. Louis Data Center
210 N Tucker, St. Louis, MO, 63101, US
At 442,000 sq ft of colocation space, 210 North Tucker is the largest building in the Netrality portfolio and the interconnection core of St. Louis, with more than 61 unique on-net providers, 36 peering networks and four exchanges in its meet-me room. It began life around 1999 as one of the two dot-com era Bandwidth Exchange carrier hotels, passed to Digital Realty in 2007, and was bought by Netrality in July 2016. Electrical plant runs to a 13,000 kW generator and 3,210 kW of N+1 UPS on diverse 13,800V feeds with 26,000 gallons of fuel. The site sits outside the 500-year floodplain and interconnects directly with 900 Walnut nearby.
Facility Specifications
Site information
- Colocation space
- 442,000 sq ft of colocation space
- Power capacity
- Diverse 13,800V utility feeds; 13,000 kW generator; 3,210 kW UPS
- Power density
- 3 to 5 kW per cabinet standard; custom builds to 12 kW per cabinet
Power & cooling
- Redundancy
- 13,000 kW generator (N, configurable to N+1) with 26,000 gallons of fuel; 3,210 kW UPS, N+1, with 2N options; N+1 condenser and chilled water; N+1 CRAC
- Cooling
- 2,000-ton open-loop condenser water, N+1, plus 800-ton closed-loop chilled water, N+1; N+1 CRAC; hot-aisle containment
Compliance
Platforms & amenities
- Platforms & services
- Single cabinets, cages, private suites and partial-floor footprints; carrier-neutral meet-me room
- Amenities
- Multi-layer security with key-card and two-factor meet-me-room access, 24/7 surveillance and NOC; outside the 500-year floodplain; office and shared-office leasing, vendor touch-down space, tech lounge and conference rooms, multi-bay loading dock
Network ecosystem — 42 carriers on-net
Notable: Arelion (Twelve99) (AS1299) · Cogent Communications, Inc. (AS174) · GTT Communications (AS3257) (AS3257) · Zayo (AS6461) · Cloudflare (AS13335) · Hurricane Electric (AS6939)
Show 12 more carriers
Colocation Packages
| Package | Size | Power | Bandwidth | Price (USD/mo) | Term | Setup | Quote |
|---|---|---|---|---|---|---|---|
| 42U Private Cabinet — 5 kW (208V A+B Redundant) | 42U — Private | 5 kW · 208V A+B | Request |
Request a Quote
- Size42U — Private
- Power5 kW
- Power Type208V A+B